01 · SearchIndoor unit modelFrom the indoor unit label, the part before the slash. Not the outdoor unit.
02 · ResultGateway, order, wiring, stepsOption 1 is the gateway plus cable, Option 2 the kit. Extra gear is listed when needed.
03 · Not listedAsk Team AirMateEngineering confirms it and we add it. Contact form or 1300 980 656.
SearchBrowse gateways
Terms used on this page
  • Indoor unit model: the number on the indoor unit label, the part before the slash. Decides compatibility. The outdoor unit number doesn't.
  • Suffix: the letters after the capacity digits (the AV1 in FDYAN100AV1). Search works with or without it.
  • Gateway: the AirTouch interface module that talks to the air conditioner. Each brand or protocol has its own, identified by a six-digit Polyaire code (657xxx).
  • Kit code: the orderable part number (672xxx) that includes the gateway and its cable. Order the kit, not the gateway.
  • Wall controller: the air conditioner's own controller. Needed during commissioning even if removed afterwards.
  • Master / Sub (also Main / Slave): which device controls the AC. Set on the gateway DIP switch and on the wall controller.
  • DIP switch: the small switches on the gateway (S1, S2, SW3). 1 = On, 0 = Off. S1 usually sets the gateway address.
  • Field setting: a hidden installer setting on the wall controller, changed with a code (for example Mode 10, code 2 to 03).
  • PCB: the printed circuit board inside the indoor unit, where the gateway wires in.
  • RS485: the two-wire link (A+, B-) between the AirTouch main module and the gateway. Cable 657211 is supplied.
  • P1 / P2 and S21: Daikin connection types. P1/P2 are wall-controller terminals on ducted and VRV units; S21 is a socket on wall-mounted and bulkhead units.
  • CN-CNT: the Panasonic wall-controller connector, 3-pin or 5-pin. Each takes a different gateway.
  • CN65: the connector on a Fujitsu indoor PCB used by the 2-wire gateway 657263.
  • NASA / Non-NASA: the two Samsung communication protocols. They take different gateways.
  • ICAMIB / ICUNO: the two ActronAir BMS (Building Management System) interface boards. Bought from ActronAir; the AirTouch gateway connects to them.
  • VRV: Daikin's multi-indoor-unit system (FX series). Compatible through gateway 657237.
  • R32: a refrigerant. Some brands changed protocol with R32 models, so the gateway or wiring differs (Gree, Samsung).
  • Model family (FDYANxxxAV1): one entry covering every capacity in a series. xxx stands for the capacity digits.
Skip to content
  • There are no suggestions because the search field is empty.

AirTouch Gateway Compatibility Search

Installer ProZone Content: compatibility, gateway part numbers, wiring and commissioning information by indoor unit model.

gateway compatibility, compatibility checker, compatible air conditioners, is my air conditioner compatible with AirTouch, which gateway do I need, gateway lookup, gateway search, kit code, wiring diagram, commissioning, DIP switch, RS485 cable 657211, indoor unit model, AirTouch 5 gateway, AirTouch 4 gateway, Actron, ActronAir, Braemar, Carrier, Daikin, Fujitsu, Gree, Haier, Bonaire, Hisense, Hitachi, LG, MDV, Midea, Mitsubishi Electric, Mitsubishi Heavy Industries, Panasonic, Rinnai, Samsung, TCL, Teco, Temperzone, Toshiba, 657217, 657219, 657220, 657222, 657229, 657237, 657238, 657239, 657244, 657245, 657246, 657248, 657252, 657259, 657260, 657263, 657264, 657265, 657266, 657267, 657273, 657274, 657275, 657276, 657277, 657279, 672125, 672127, 672128, 672129, 672130, 672131, 672132, 672133, 672134, 672135, 672136, 672137, 672138, 672158, 672176, 672177, 672178, 672202, 672203, NASA, Non-NASA, P1 P2, S21, CN-CNT, CN65, ICAMIB, ICUNO, X1 X2, H1 H2, VRF, VRV, ducted, split system, cassette, bulkhead, wall mounted